Axis Studio Release Notes | Perception Neuron Motion Capture

Axis Studio Release Notes
------------------------------------------
Release date: Jun.24.2022
Version:2.8.12369.1831
Previous version:2.7.12222.1720

------------------------------------------
Latest Firmware Version:
PNS RF Transceiver:6.9.9.7
PNS Sensor:6.3.21.17
PNS Gloves:6.3.15.20
PNS Plus Sensor:11.0.9.255

PN3 Transceiver:9.9.9.34
PN3 Sensor:9.3.8.14
------------------------------------------
CHANGES IN VERSION 2.8.12369.1831

New Features:
1. Added a new feature of Mag Trajectory display. Button located in the viewport
2. Added two types of new skeleton for animation retargeting which are“Metahuman”and“UE_Mannequin”in BVH broadcasting module.
3. Added support to replace any finger sensor with PN3 spare sensor.
4. Added an activation link in License Check window via clicking "No Activation Code" to get.
5. Added support to two-way communitcation. Please refer to MocapAPI.
6. Added a new feature where Pose Calibration settings are now saved.

------------------------------------------
Improvements and Changes:
1. Removed 【Magnetic immunity】 button function and set it enable as default when Gloves device connected.
2. Removed "Sensor Steady checking" function when connecting.
3. Changed Posture Calibration default poses as A-W-B for Fullbody +Gloves working mode,T-pose and P-pose are optional for now.

------------------------------------------
Bug fixed:
1. Fixed a crash problem caused by not supporting Chinese encoding for NIDS network.
2. Fixed a problem that Hip position will display error after perform data process when using Hip locked scenario.
3. Fixed a bug of allowing "Finger constraint" radio box being empty value.
4. Fixed a problem that Axis Studio failed to launch in some certain cases with valid ativacation code.
5. Fixed a bug of missing【Active】button.
6. Fixed several text spelling errors.

------------------------------------------
Known Issues:
1. Axis Studio may fail to check device Firmware in some certain cases and that will prevent device being firmware upgraded.
Workaround:Turn off two sensors(right upleg and hip) and on again manually and then recheck firmware.
2. Hardware fault error may occur sometimes which usually in the form of sensors connection failure or being abnormal indicator lights.
Workaround: Turn it off and on again mannually.
3. Data process algorithm of v2.6 and later is not compatible with the motion capture data recorded in previous version.
Thumb motion data generated from previous version will be wrong after data processing in v2.6
4. Space locked scenario doesn't take effect after Data processing.
5. When upgrading sensor firmware Axis Studio sometimes will indicate sensors in low battery but actually all sensors are fully charged
Workaround: Try to reconnect or check again can solve this error checking problom.
6. Drag/Extend Axis Studio window to another monitor which is in a different resolution will cause Axis Studio crash
Workaround: Dragging Axis Studio onto the extended screen while opening its Project tab
7. 3rd Party software running Screen Word Fetching function may cause Axis Studio crash while opening files
8. Ctrl + A shortcut only works for X-Ray function
9. Resize Axis Studio window while viewport is split screen mode may cause wrong window size issue
10. Display frame rate of Axis Studio may decrease if MotionBuilder is running on the same computer at the same time
Workaround: Mobu >System ProfilingCenter >Evaluation select Always refresh view

------------------------------------------
Release date: Mar.31.2022
Version 2.7.12222.1720
Previous version 2.7.12179.1680

------------------------------------------
Latest Firmware Version
PNS Transceiver 6.9.9.6
PNS Sensor 6.3.21.17
PNS Gloves 6.3.15.20
PN3 Transceiver 9.9.9.34
PN3 Sensor 9.3.8.14
------------------------------------------
CHANGES IN VERSION 2.7.12179.1680
New Features:
1. Added an option of 5s for "Button delay" function in Advanced settings window.
   This setting applies to: Resume Original Posture button/Zero button/Reset baseline button/Record button.
2. Perception Neuron Studio body sensors can change frequency by double clicking on the power button.
3. Introduced the 'CONNECT' button, located in the suits panel. Requires performer to maintain an A-POSE to connect sensors to Axis Studio.
4. Changed posture calibration sequence order.
5. Introduced the W-POSE in the posture calibration sequence. W-POSE helps improve the motion capture overall anti-mag 
6. Added G-Button. Helps reset magnetic baseline for the magnetometers.

------------------------------------------
Improvements and Changes
1. Restored 'Resume Original Posture' function.
2. Updated Sample Project.
------------------------------------------
Bug fixed
1. Fixed a problem that it didn't work immediately after switching Frame Format Type in BVH Broadcasting.
2. Fixed a crash problem when deleting file(s) in Project tab which is caused by access denied.
3. Fixed a problem of not saving body size after closing mbx file.
4. Fixed several text spelling errors.
------------------------------------------
Known Issues:
1. Data process algorithm of v2.6 and later is not compatible with the motion capture data recorded in previous version.Thumb motion data generated from previous version will be wrong after data processing in v2.6
2. Space locked scenario doesn't take effect after Data processing.
3. When upgrading sensor firmware Axis Studio sometimes will indicate sensors in low battery but actually all sensors are fully charged. Workaround: Try to reconnect or check again can solve this error checking problom.
4. Hip position will display error after perform data process when using Hip locked scenario.
5. Drag/Extend Axis Studio window to another monitor which is in a different resolution will cause Axis Studio crash. Workaround: Dragging Axis Studio onto the extended screen while opening its Project tab
6. 3rd Party software running Screen Word Fetching function may cause Axis Studio crash while opening files
7. Ctrl + A shortcut only works for X-Ray function
8. Resize Axis Studio window while viewport is split screen mode may cause wrong window size issue
9. Display frame rate of Axis Studio may decrease if Motionbuilder is running on the same computer at the same time. Workaround:  Mobu> System ProfilingCenter >Evaluation  select always refresh view

------------------------------------------
Release date: Aug.19.2021
Version::2.5.11768.1331
Previous version:2.4.11640.1243

------------------------------------------
Latest Firmware Version:
PNS Transceiver:6.5.3.2
PNS Sensor:6.2.3.6
PNS Gloves:6.1.12.5

PN3 Transceiver:9.2.3.4
PN3 Sensor:9.2.2.0
------------------------------------------
CHANGES IN VERSION 2.5.11768.1331

New Features:
1. Added support of multi-PN3 mocap suit connection,  maximum number is three:Use three transceivers of three channels  
    The latest version (9.2.3.4) of transeciver firmware is required, and Axis Studio license need be upgraded
2. Added two more channel options for PN3 mocap suit 
    The function that double click sensor button to switch to new channel requires the latest version (9.2.2.0) of sensor firmware
3. Added support of multi-PNS mocap suits connection using USB mode, maximum number is five 
4. Added [Character Skeleton Property] setting in skeleton panel to set customized character skeleton type for each character when live streaming bvh data  
    Select "Customized Character Skeleton" in BVH broadcasting window to use it
5. Added Simplified Body Dimension input mode.
6. Added Range of Motion (*.csv) type file export function
    It is required to have Axis Studio license upgrade

------------------------------------------
Improvements and Changes:
1. keep Camera Following still active after you translate or rotate camera perspective
2. Updated the Robot model to get better mocap accurateness

------------------------------------------
Bug fixed:
1. Fixed several problems that failed to calculate sensor's posture in certain cases
2. Fixed a problem that Timecode attribute of motion file in Project page display incorrectly 
3. Fixed several spelling errors
4. Fixed several crash problems

------------------------------------------
Known Issues:
1. Drag/Extend Axis Studio window to another monitor which is in a different resolution will cause Axis Studio crash 
 (Workaround: Drag Axis Studio when it in its Project tab )
2. PN3 sensor may connected failed under certain condition, manually restart the sensor can make it work normally  
3. Camera following function can only work in horizontal plane, doesn't work in vertical plane (Avatar goes up and down)
4. 3rd Party software running Screen Word Fetching function may cause Axis Studio crash while opening files
5. In [Connect with Wizard] connection (Especially in 6-axis connection mode) or steady calibration, all sensors must be steady (still and not moving) otherwise, the pose calculation will be incorrect. Restart Axis Studio and redo steady calibration in the right way may solve this problem
6. Ctrl + A shortcut only works for X-Ray function
7. Resize Axis Studio window while viewport is split screen mode may cause wrong window size issue
8. Display frame rate of Axis Studio may decrease if MotionBuilder is running on the same computer at the same time 
    (Solution: Mobu >System ProfilingCenter >Evaluation select Always refresh view)

------------------------------------------
Release date: Aug.6.2021
Version: 2.5.11752.1310
Previous version:2.4.11640.1243

------------------------------------------
Latest Firmware Version:
PNS Transceiver:6.5.3.2
PNS Sensor:6.2.3.6
PNS Gloves:6.1.12.5

PN3 Transceiver:9.2.3.4
PN3 Sensor:9.2.2.0
------------------------------------------
CHANGES IN VERSION 2.5.11752.1310

New Features:
1. Added support of multi-PN3 mocap suit connection,  maximum number is three:Use three transceivers of three channels  
    The latest version (9.2.3.4) of transeciver firmware is required, and Axis Studio license need be upgraded
2. Added two more channel options for PN3 mocap suit 
    The function that double click sensor button to switch to new channel requires the latest version (9.2.2.0) of sensor firmware
3. Added support of multi-PNS mocap suits connection using USB mode, maximum number is five 
4. Added [Character Skeleton Property] setting in skeleton panel to set customized character skeleton type for each character when live streaming bvh data  
    Select "Customized Character Skeleton" in BVH broadcasting window to use it
5. Added Simplified Body Dimension input mode.
6. Added Range of Motion (*.csv) type file export function
    It is required to have Axis Studio license upgrade

------------------------------------------
Improvements and Changes:
1. keep Camera Following still active after you translate or rotate camera perspective
2. Updated the Robot model to get better mocap accurateness

------------------------------------------
Bug fixed:
1. Fixed several problems that failed to calculate sensor's posture in certain cases
2. Fixed a problem that Timecode attribute of motion file in Project page display incorrectly 
3. Fixed several spelling errors
4. Fixed several crash problems

------------------------------------------
Known Issues:
1. Drag/Extend Axis Studio window to another monitor which is in a different resolution will cause Axis Studio crash 
 (Workaround: Drag Axis Studio when it in its Project tab )
2. PN3 sensor may connected failed under certain condition, manually restart the sensor can make it work normally  
3. Camera following function can only work in horizontal plane, doesn't work in vertical plane (Avatar goes up and down)
4. 3rd Party software running Screen Word Fetching function may cause Axis Studio crash while opening files
5. In [Connect with Wizard] connection (Especially in 6-axis connection mode) or steady calibration, all sensors must be steady (still and not moving) otherwise, the pose calculation will be incorrect. Restart Axis Studio and redo steady calibration in the right way may solve this problem
6. Ctrl + A shortcut only works for X-Ray function
7. Resize Axis Studio window while viewport is split screen mode may cause wrong window size issue
8. Display frame rate of Axis Studio may decrease if MotionBuilder is running on the same computer at the same time 
    (Solution: Mobu >System ProfilingCenter >Evaluation select Always refresh view)

------------------------------------------
Release date: July.12.2021
Version: 2.4.11605.1264
Previous version: 2.4.11579.1201

------------------------------------------
New Features:
1. Added Timecode data visualization in Hybrid mode
Improvements:
1. Optimized the performance of 3D viewport render
Changes:
1. Restored 2.3 version of "Axis Studio -Thumb Open" skeleton output and exporting
2. Upgraded sample project
3. Changed the skeleton type name from "Maya(Beta)" to "Maya/MOBU/Human IK (Beta)" in BVH broadcasting and file Exporting
4. Removed the display of the online transceiver's numbers
Bug fixed:
1. Fixed a crash problem when launching Axis Studio without administration permission in some certain circumstance
2. Fixed a problem that failed to upgrade PNS transceiver firmware via USB connection
3. Fixed several spelling mistakes
4. Fixed a problem about checkbox of suit panel in hybrid mode
5. Fixed a memory leak problem\
------------------------------------------
Release date: May.28.2021
Version: 2.4.11579.1201
Previous version:2.3.11193.992

------------------------------------------
Latest Firmware Version:

PNS Transceiver:6.5.3.2
PNS Sensor:6.2.3.6
PNS Gloves:6.1.12.5

PN3 Transceiver:9.2.0.0
PN3 Sensor:9.2.0.0
------------------------------------------
CHANGES IN VERSION 2.4.11579.1201

New Features:
1.Added Timecode data visualization
2.Added PN3 device support
3.Added Calc data broadcasting function
4.Added magnetic data on/off  function in Float mini controller
5.Added 4 different reference skeletons for file export and data broadcasting

------------------------------------------
Improvements:
1.Optimized the Transceiver identification ability
2.Optimized the Wizard process
3.Optimized the UI of sensor map by adding finger display
4.Optimized the UI of settings window
5.Optimized PN Avatar 3D model
6.Optimized the UI of the FBX file export settings panel

------------------------------------------
Changes:
1.The 3ds Max biped bvh export feature is merged into bvh export module
2.Change the default export FPS from 90fps to 96fps
3.Change "Hands/Hip contact  height auto detect" to be unchecked by default
4.Change the default body dimension name of PN Avatar from“PNS Robot”to“PN Robot”
5.Add PN3 sample files in Sample Project

------------------------------------------
Bug fixed:
1. Fixed a problem that recorded data may have synchronized error under certain condition when using Multi-transceivers to connect Multi-suits
2. Fixed a problem that failed to rename file when export multi-character file
3. Fixed a problem that failed to hide character name  in 3D viewport
4. Fixed a crash problem when exporting invalid file

------------------------------------------
Known Issues:
1. Firmware upgrade for PNS transceiver via USB mode connection may fail , restart Axis Studio can make it work normally
2. PN3 sensor may connected failed under certain condition, manually restart the sensor can make it work normally 
3. Check box in Device List may work abnormal in hybrid mode
4. Drag Axis Studio window to another monitor which is in a different resolution will cause Axis Studio crash
(Workaround: Drag Axis Studio when it in its Project tab will not crash )
5. In [Connect with Wizard] connection (Especially in 6-axis connection mode) or steady calibration, all sensors must be steady (still and not moving) otherwise, the pose calculation will be incorrect. Restart Axis Studio and redoing steady calibration the right way may solve this problem
6. Camera following function can only work in horizontal plane, doesn't work in vertical plane (Avatar goes up and down)
7. Ctrl + A shortcut only works for X-Ray function
8. 3rd Party software running Screen Word Fetching function may cause Axis Studio to crash while opening files
9. Resize Axis Studio window while viewport is split screen may cause wrong window size issue
11. Display frame rate of Axis Studio may decrease if MotionBuilder is running on the same computer at the same time (Solution: Mobu >System ProfilingCenter >Evaluation select Always refresh view)

 
------------------------------------------
Release date: Dec.31.2020
Version: 2.3.11193.992
Previous version:2.2.11050.893

------------------------------------------
Latest Firmware Version:
Transceiver:6.5.2.1
Sensor:6.2.3.6
Gloves:6.1.12.5
------------------------------------------
CHANGES IN VERSION 2.3.11193.992:

New Features:
1. Added a new algorithm that there's no gap between Joints. Only works for recorded data after Data Process. To turn on this algorithm: Main menu >Settings >Advanced Settings>Joint Space "Off";
2. Added Advanced Settings window in Main menu, include "Joint Space" and "Finger Constrained";
3. Added Hands/Hip contact height auto detect function, which will allow the user to capture data with foot on the floor while Hip/Hands contact above the floor;
4. Added .calc data file export function;
5. Added ability to save Body Dimension modification directly in Editing tab;
6. Added displays of Working Mode and Data FPS in Sensor map panel;
7. Added abilty of Standard Calibration and Firmware Upgrading to Hybrid PWR Tracker
------------------------------------------

Improvements:
1. Improved devices connection stability;
2. Improved the accuracy of foot contact algorithm;
3. Optimized the tab page layout in the Main menu> settings;
4. Optimized the UI of the FBX file export settings;
5. Updated the Robot model to get better adapt the foot contact algorithm;
6. Optimized the Wizard process
------------------------------------------

Changes:
1. Removed the "Large Dynamic" option from Constraint Mode list of Solver Parameter (Normal mode is able to fit the large dynamic mocap already);
2. Contact Indicator hide by default;
3. Modified the color of the coordinate to RGB correspond to XYZ
------------------------------------------

Bug fixed:
1. Fixed a problem of not appling proper palm size to the exported biped.bvh file;
2. Fixed a firmware upgrading failed problem under certain condition;
3. Fixed a problem that Axis failed to open recorded file which caused by necessary information missing;
4. Fixed a problem that Axis Studio failed to connect device after firmware upgrading under certain condition;
5. Fixed a problem that the transceiver cannot be successfully connected on certain PC models;
6. Fixed the problem that sensor signal display zero under certain condition;
7. Fixed a problem that failed to create root folder in current project;
8. Fixed several crash problems
------------------------------------------

Known Issues:
1. Multiple devices connection process is slow;
2. In [Connect with Wizard] connection (Especially in 6-axis connection mode) or steady calibration, all sensors must be steady (still and not moving) otherwise, the pose calculation will be incorrect. Restart Axis Studio and redoing steady calibration the right way may solve this problem;
3. Firmware upgrade for Sensors and Gloves can only be done with 60% battery life or more (2/4 battery bars);
4. Camera following function can only work in horizontal plane, does work in vertical plane (Avatar goes up and down);
5. Ctrl + A shortcut only works for X-Ray function;
7. 3rd Party software running Screen Word Fetching function may cause Axis Studio to crash while opening files;
8. Resize Axis Studio window while viewport is split screen may cause wrong window size issue;
9. Display frame rate of Axis Studio may decrease if Motion builder is running on the same computer at the same time; (Workaround: Mobu >System ProfilingCenter >Evaluation select Always refresh view);
10. Recorded data may have synchronized error under certain condition when using Multi-transceivers to connect Multi-suits.
------------------------------------------
Release date: Dec.1.2020
Version: 2.2.11050.893
Previous version:2.1.10810.776

------------------------------------------
Latest Firmware Version:
Transceiver:6.5.2.1
Sensor:6.2.3.6
Gloves:6.1.12.5
------------------------------------------
CHANGES IN VERSION 2.2.11050.893:

New Features:
1.Added ability to restore the processed motion data by cliking [Revert to origin] button 
Notes: Click [Revert to origin] button will restore contact editing process and parameter editor and body dimentions
2.Added ability to manage individual suit in Muti-suit mode such as connect,sleep,poweroff
3.Added ability to batch Export/Import/Delete files and supported to import files by dragging and dropping
4.Added Hip contact algorithm
5.Added ability to export T-pose reference bone only as fbx file.(Unchecking "Motion Data" checkbox in Export Settings)
6.Added Perception Neuron Studio -Thumb open skeleton option for data streaming and file exporting

------------------------------------------
Improvements:
1.Optimized hand contact performance in Single level mode 
2.Added "Export" option in Right-Click menu
3.Optimized biped.bvh export to adapt the "Limb Orientation/angle" import settings to solve the arm twisting problem in 3ds Max 
4.Optimized the UI of Device list panel
5.Improved performance of feet solidity on the ground  

------------------------------------------
Changes:
1.Added Wibu Dongle CodeMeter authorization 
2.Added default algorithm parameter modes: Normal mode,Large Dynamic and Steady Contact
3.Change the default reference skeleton to be "Perception Neuron Studio -Thumb open" for data streaming and file exporting
4."Displacement" checked by default in both Export settings and Broadcasting windows
5.Updated the sample project with adding two Hip contact sample data
6.Disable switch "Working mode" function while doing realtime mocap 

------------------------------------------
Bug fixed:
1. Fixed an issue that connect device filed after swiching channel in some certain case
2. Fixed a crash issue when Manually set the Transceiver network during the auto detect process
3. Fixed an issue that failed to clear up characters info after detecting no devices online
4. Fixed a crash issue of lanuching Axis Studio in some certain case

------------------------------------------
Known Issues:
1. Multiple devices connection will be slow
2. In [Connect with Wizard] connection (Especially in 6-axis connection mode) or steady calibration, all sensors must be steady (still and not moving) otherwise, the pose calculation will be incorrect. Redoing steady calibration the right way may solve this. If not, restart Axis
3. Channel LED indicator not supported for PNS gloves
4. Firmware upgrade for Sensors and Gloves can only be done with 60% battery life or more (2/4 battery bars)
5. Camera can only follow the 3D character which moves in a straight line in 3D view
6. Ctrl + A is reserved as a shortcut for x-ray function in Axis Studio which means it's not working if you set it as a key for other functions
7. 3rd Party software running Screen Word Fetching function may cause Axis Studio to crash while opening files
8. Resize Axis Studio window while viewport is split screen may cause wrong window size issue
9. Display frame rate of Axis Studio may decrease if Motion builder is running on the same computer at the same time
    Workaround: Mobu >System ProfilingCenter >Evaluation select Always refresh view

------------------------------------------
Release date: Aug.21.2020
Version: 2.1.10810.776
Previous version:2.0.10702.707

------------------------------------------
Latest Firmware Version:
Transceiver:6.5.2.1
Sensor:6.2.3.6
Gloves:6.1.12.5
------------------------------------------
CHANGES IN VERSION 2.1.10810.776:

New Features:
------------------------------------------
Improvements:
------------------------------------------
Changes:
1. Restored original Perception Neuron Studio reference skeleton for data streaming and file exporting
2. Added a Body Dimension file for PNS standard model which is called "PNS Robot".
------------------------------------------
Bug fixed:
1. Fixed an issue of time synchronization in Muti-Character mode
2. Fixed an issue about name convention of (.biped.bvh) format file. 
------------------------------------------
Known Issues:
1. Manually selecting the Transceiver network during the auto detect process (about 5 seconds after powering on the Transceiver) may cause Axis Studio crash issues.
2. [Connect with Wizard] function only supports one PNS suit, multi-sets will be supported in the future.
3. In [Connect with Wizard] connection (Especially in 6-axis connection mode) or steady calibration, all sensors must be steady (still and not moving) otherwise, the pose calculation will be incorrect. Redoing steady calibration the right way may solve this. If not, restart Axis.
4. Channel LED indicator not supported for PNS gloves
5. [Resume Original posture] requires a steady A POSE
6. Firmware upgrade for Sensors and Gloves can only be done with 60% battery life or more (2/4 battery bars)
8. Camera can only follow the 3D character which moves in a straight line in 3D view
9. Setting Ctrl + A as a shortcut is not supported
10. 3rd Party software running Screen Word Fetching function may cause Axis Studio to crash while opening files.
12. Axis Studio viewport split screen does not support responsive layout
13. Display frame rate of Axis Studio may decrease if Motion builder is running on the same computer at the same time
    Workaround: Mobu >System ProfilingCenter >Evaluation select Always refresh view
14. Process [Resume original posture] may cause error posture in Muti-Character mode
15. Foot contact indicator may display in the wrong position in some certain cases

------------------------------------------
Release date: July.22.2020
Version: 2.0.10702.707
Previous version:1.3.10119.302

------------------------------------------
Latest Firmware Version:
Transceiver:6.5.2.1
Sensor:6.2.3.6
Gloves:6.1.12.5
------------------------------------------
CHANGES IN VERSION 2.0.10702.707:
 

New Features:
1. Added a connection wizard to guide users on how to operate PNS suit correctly through a series of steps by clicking the [Connect with Wizard] function.
2. Added a new feature to hide/show the panel with the mouse click on the sidebar arrow
3. Added sensor signal, magnetic and battery info into data record/replay [Editing]
4. Added Simplified Mandarin language support : Menu > Settings > Language
5. Added a new feature for multi-stream support by adding broadcasting options for Capture/Live and Editing/Playback
6. Added VRPN supported for output
7. Added support to select frame rate for file exporting
8. Added support to export biped.bvh format files containing finger data 
9. Added support to export .fbx and .bvh format files with displacement data 
10. Added a new feature to automatically find transceiver’s IP address after network setup has been set up correctly [must be using Transceiver version 6.5.2.1 or higher and in USB mode]
11. Added B-pose and P-pose calibration to improve hand and finger performance
12. Added battery “Sensor Energy Saving” mode - All the sensors (excluding gloves) will power off automatically if left on idle for more than 5 minutes. 
13. Added 50fps supported for capture
14. Added "true anti-magnetic mode": set [Magnetic turn off] before connection, and connect with Wizard
15. Added Glove Magnetic calibration tutorial in Main Menu >Magnetic Calibration
16. Added right-click menu in [Take Information] panel of both capturing and Editing windows which include:  "open", "rename", "delete" and "show in explore" options
17. Added Glove only working mode   
18. Added frequency color indicator onto Axis Studio’s avatar
19. Added function to prevent PC from sleeping automatically when Perception Neuron Studio is in working mode(Data capturing or firmware updating) 
20. Added several user shortcuts
21. Added a function to automatically detect required posture calibrations based on working mode 
22. Added Working Mode instructions in the Main Menu : Main Menu > Working Mode Introduction
23. Added Sensor Firmware update and reminder alert
 

------------------------------------------
Improvements:
1. Optimized jump height issue
2. Optimized leg posture shaking issue when landing from high-dynamic movements
3. Improved performance of feet solidity on the ground 
4. Optimized hand contact performance
5. Optimized Software 3D Rendering for Avatar Model, Camera-following, Floor Transparency, Shadow and Font style
6. Improved built-in anti-mag capability
7. Optimized the sensor calibration algorithm
9. Remove requirement to manually disconnect before performing magnetic calibration or frequency setting 
10. Added ability to power on all body sensors placed in the charging box when charging cord is removed [must be using Sensor version 6.5.2.1 or higher]
 

------------------------------------------
Changes:
1. Updated firmware upgrade interaction 
2. Updated the software splash screen
3. Unset camera following when perform Rotate or Pan
4. Updated Measurement Guide illustration
5. Updated Magnetic Calibration tutorial
6. Disable the [Finish] button before clicking [Switch] button in Frequency settings wizard
7. When creating a new project, "Enter" button works as "OK to create"
8. Set ‘Solver Parameter’ tab as default when opening a file in the Editing Workspace.
9. In Capture Workspace, reconnect will not reset the display page to sensor map anymore
10. Redefined Perception Neuron Studio reference skeleton for data streaming and file exporting
11. Remove the NUE coordinate display in the left lower corner of 3D scene
12. Adjust name/definition of the motion capture parameters 
13. Removed "Add T pose" option when exporting biped.bvh format file
14. Removed UDP protocol option in Advanced BVH Broadcast as it is not currently supported externally.
15. Set localhost as the default in BVH broadcasting
16. Replaced Actor ID for Actor index in the frame header of BVH Broadcasting
 

------------------------------------------
Bug fixes:
1. Fixed erratic PNS glove posture lock [must be using latest firmware version of gloves 6.1.12.5]
2. Fixed an issue when recording time is displayed incorrectly 
3. Fixed missing ‘Foot Length’ field when viewing Project > Body Dimension
5. Fixed Transceiver not detected by Axis Studio when working offline
6. Fixed rapid finger flipping due to magnetic interference or wrong posture
7. Fixed a crash bug during Axis Studio startup
8. Fixed intermittent issue that prevented biped.bvh export
9. Fixed an error with T-pose motion capture data exported from Axis Studio
10. Fixed an error with motion capture data containing PN/PN pro skeleton exported from Axis Studio
11. Fixed 3D character scaling problem
12. Fixed several 4k resolution display problems
 

------------------------------------------
Known Issues:
1. Manually selecting the Transceiver network during the auto detect process (about 5 seconds after powering on the Transceiver) may cause Axis Studio crash issues.
2. ‘Connect with Wizard’ function only supports one PNS suit, multi-sets will be supported in the future.
3. In [Connect with Wizard] connection (Especially in 6-axis connection mode) or steady calibration, all sensors must be steady (still and not moving) otherwise, the pose calculation will be incorrect. Redoing steady calibration the right way may solve this. If not, restart Axis.
4. Channel LED indicator not supported for PNS gloves
5. [Resume Original posture] requires a steady A POSE
6. Firmware upgrade for Sensors and Gloves can only be done with 60% battery life or more (2/4 battery bars)
8. Camera can only follow the 3D character which moves in a straight line in 3D view
9. Setting Ctrl + A as a shortcut is not supported
10. 3rd Party software running Screen Word Fetching function may cause Axis Studio to crash while opening files.
12. Axis Studio viewport split screen does not support responsive layout
13. Display frame rate of Axis Studio may decrease if Motion builder is running on the same computer at the same time
    Workaround: Mobu >System ProfilingCenter >Evaluation select Always refresh view
14. process [Resume original posture] may cause error posture in Muti-Character mode
15. Foot contact indicator may display in the wrong position in some certain cases

About Perception Neuron

We are part of Noitom Ltd. and dedicated to the development of motion capture systems for entertainment, sports, science and medicine.

  • 278 NE 60 St
    Miami, Florida 33137
  • (305) 521-3124
  • +86 10 82055391 ext. 852
  • contact@neuronmocap.com

Latest Posts